Rise and Run: The Fundamentals
IRC R311.7.5 specifies: maximum rise of 7-3/4 inches, minimum run of 10 inches, and maximum variation between adjacent risers of 3/8 inch, and between the largest and smallest riser in a flight of 3/8 inch. That last requirement is the one that trips people up. You can't have one riser at 7" and another at 7.5" in the same stair run — the variation can't exceed 3/8". This means your total rise must be carefully divided into equal-or-nearly-equal increments before you cut a single stringer.
Calculate Total Rise Carefully
Measure from finished floor to finished floor — including the finish material on both levels. If the main floor gets 3/4" hardwood and the upper floor gets 1/2" carpet pad plus 1/2" carpet, that's 1.75" of material affecting your total rise. Cut your stringers before flooring is installed and account for every layer. Getting this wrong means reworking the entire stair.
Headroom
Minimum 6'-8" of headroom, measured vertically from the stair nosing to the ceiling or obstruction above. Measure the actual headroom on the line of travel — not just at the top of the stair. A beam running parallel to the stair at the landing is a common headroom problem discovered at final inspection.
Handrails and Guards
Handrails are required on stairs with 4 or more risers — one side minimum, both sides if the stair is 44" or wider. Handrail height: 34" to 38" above stair nosings. The handrail must be "graspable" — a specific term with dimensional requirements (IRC R311.7.8). A 2x6 flat rail doesn't qualify. Use a profile that has a graspable shape — round, oval, or shaped profiles that meet the dimensional criteria.
Guards are required where open sides of stairs are more than 30" above grade. Minimum 36" height on residential stairs, 42" where required by occupancy. Balusters spaced so a 4" sphere cannot pass through.