Smoke and carbon monoxide detector requirements have tightened significantly over the last decade. This is one of those areas where inspectors look carefully and where getting it wrong creates real safety liability. Know the current requirements before you frame your next job.
Smoke Alarm Placement — IRC Requirements
The 2021 IRC (R314) requires smoke alarms in: each sleeping room, outside each sleeping area in the immediate vicinity of the bedrooms, on every level of the dwelling including the basement, and in habitable portions of the attic. "Outside the sleeping area" means in the hall immediately adjacent to bedroom doors — not at the end of a long hallway.
Interconnection is Now Required
All smoke alarms in new construction must be interconnected. When one sounds, they all sound. This is critical in larger homes where a basement alarm might not wake someone sleeping on the second floor. Interconnection can be hardwired or, in many jurisdictions, wireless-interconnected using alarms with RF communication. Verify local acceptance of wireless interconnection before specifying it.
Power Requirements
Smoke alarms in new construction must be hardwired with battery backup. Battery-only alarms are not code-compliant for new construction. The circuit should be dedicated or on a general lighting circuit — not GFCI-protected (GFCI trips can inadvertently kill alarm power).
Carbon Monoxide Alarms
IRC R315 requires CO alarms in dwelling units with fuel-fired appliances or attached garages. Placement: outside each sleeping area and on every level. CO is heavier than air in some conditions, but CO alarms should be mounted at the height recommended by the manufacturer — typically mid-wall to ceiling height, not at floor level. A common mistake is installing CO detectors at floor level "because CO is heavy" — CO density relative to air is nearly the same and this isn't the right approach.
Combination Alarms
Combination smoke/CO alarms are code-compliant in most jurisdictions and simplify installation. Verify they meet the listed requirements for both smoke (UL 217) and CO (UL 2034) and that they're interconnectable if required.
The Bottom Line
Smoke and CO alarms are life-safety equipment. Install them right — correct placement, hardwired, interconnected. Don't guess on this one. Pull out the IRC, check local amendments, and document the installation before drywall covers your wiring.