As houses get tighter — better windows, more air sealing, better vapor control — natural infiltration no longer provides adequate fresh air. A house that passes a blower door test at 2 ACH50 or below needs mechanical ventilation. This is code in many jurisdictions and simply good building science everywhere.
The Problem With Tight Houses
A tight house without mechanical ventilation accumulates CO2, VOCs off-gassed from building materials and furnishings, cooking byproducts, moisture from occupant activity, and combustion gases. Indoor air quality problems in tight houses aren't hypothetical — they're a documented health issue. The solution is deliberate, controlled ventilation rather than random infiltration.
ASHRAE 62.2: The Standard
ASHRAE 62.2 is the residential ventilation standard and is referenced by most energy codes. It specifies minimum whole-house ventilation rates based on conditioned floor area and number of bedrooms. The formula: 0.03 × floor area (sq ft) + 7.5 × (bedrooms + 1) = minimum CFM. A 2,500 sq ft 4-bedroom house needs about 112 CFM of continuous ventilation.
Ventilation Strategies
Exhaust-only: A bath fan runs continuously or intermittently, exhausting air and drawing makeup air through intentional inlets. Simple and cheap, but creates negative pressure — can backdraft combustion appliances and draw unconditioned air in at random locations. Supply-only: A fan pushes outdoor air into the house. Creates positive pressure — good in cold climates to reduce moisture infiltration, but can drive moisture into wall assemblies in hot-humid climates. Balanced (HRV/ERV): Balanced exhaust and supply with heat recovery. More expensive but the right solution for high-performance buildings. See our earlier article on HRV/ERV selection.
Bath Fans as Ventilation
Using intermittently-operated bath fans as the ventilation system can satisfy ASHRAE 62.2 with a calculation adjustment for intermittent operation. An intermittent fan needs to run more CFM to compensate for the time it's off. This approach works but requires the fan to actually run — occupants need to have good habits, or it needs to be on a timer. Passive reliance on "people will open windows" doesn't satisfy code.
The Bottom Line
Build tight, ventilate right. If you're sealing the house to reduce energy use, you're also responsible for providing fresh air mechanically. Know the local code requirements and specify ventilation accordingly. It's health, not just energy.