Most contractors hand the geotechnical report to the engineer and move on. That's reasonable — soil analysis is a specialty. But understanding the basics helps you ask better questions, anticipate problems, and avoid being blindsided mid-excavation. Foundation problems are among the most expensive construction issues to fix after the fact.
What's in a Geotech Report
A geotechnical investigation report typically includes: boring logs showing soil composition at various depths, laboratory test results (moisture content, plasticity, compaction characteristics), bearing capacity recommendations, and specific foundation type recommendations. It may also include groundwater depth, expansive soil potential, and recommendations for subgrade preparation.
Soil Classification
The USCS (Unified Soil Classification System) classifies soils by grain size and plasticity. GW and GP = gravel (good for bearing). SW and SP = sand (good to acceptable). ML and CL = silt and clay (problematic). CH = high-plasticity clay (problem soil). MH = elastic silt (problem soil). Organic soils (OL, OH, PT) = essentially unbuildable without removal. The boring logs use these codes at different depths. Understanding them tells you what you're building on.
Allowable Bearing Capacity
This is the number that sizes your footings. The report will specify allowable bearing pressure in pounds per square foot (psf) or kips per square foot (ksf). Dense gravel: 3,000–8,000 psf. Dense sand: 2,000–4,000 psf. Firm clay: 1,500–3,000 psf. Soft clay: 500–1,500 psf. The structural engineer uses this number to size footings. If actual soil conditions during excavation differ from the report, stop and call the engineer.
Expansive Soils
Clay soils shrink when dry and swell when wet. High-plasticity clays (CH) can have swell potential of 5–10% — enough to lift a slab, crack foundations, and destroy plumbing over time. If the report identifies expansive potential, the foundation design must account for it: typically with deeper footings below the active zone, structural slabs instead of slabs-on-grade, or chemical soil treatment.
Groundwater
The report notes groundwater depth at time of investigation. Seasonal groundwater can be significantly higher than observed. If groundwater is within 3–4 feet of footing depth, waterproofing strategy changes significantly — and structural concrete mix designs may need to be modified for sulfate resistance.
The Bottom Line
Read the executive summary and recommendations section. Know the bearing capacity, the soil classification, and whether expansive soils or groundwater are concerns. When conditions in the field don't match the report — and they sometimes don't — call the engineer before you pour concrete.