Grounding and bonding are among the most misunderstood concepts in residential electrical. "Aren't they the same thing?" No. They serve different functions, and mixing them up in conversation with your electrical sub (or an inspector) signals that you don't know what you're talking about. Here's the practical distinction.
Bonding: Connecting Metal Parts Together
Bonding connects all metal parts of an electrical system — and metal objects near it — to create a common electrical reference point. The goal is to ensure that if a fault occurs, all metal parts are at the same potential relative to each other. This prevents voltage differences between, say, a metal water pipe and a metal appliance frame that could shock someone who touches both simultaneously. Bonding keeps everything "at the same level."
Grounding: Connecting to Earth
Grounding connects the electrical system to earth — literally to the ground beneath the building. The earth serves as a reference point (0 volts) for the electrical system. Grounding provides a path for fault current to flow back to the source (the utility transformer) in the event of a ground fault, which trips breakers and protects people. Without grounding, fault current might find its path through a person.
The Practical Distinction
Bonding is about connecting things to each other. Grounding is about connecting the system to earth. Both are required. A system can be bonded but not grounded (common in some isolated systems) or grounded but with inadequate bonding. In residential construction, both happen simultaneously at the main panel, where the ground bus and neutral bus are typically bonded to earth via the grounding electrode system.
The Grounding Electrode System
The NEC requires a grounding electrode system — the connection between the electrical system and earth. This typically includes ground rods (minimum 8 feet, driven to full depth), the metal water service pipe (if it has 10+ feet underground), and concrete-encased electrodes (rebar in footings — the "Ufer ground"). Using the rebar in footings as part of the grounding electrode system is cost-effective and provides an excellent ground — specify it in your electrical scope when pouring footings.
The Bottom Line
You don't need to design electrical systems, but understanding what grounding and bonding do helps you verify that your electrical sub is discussing the right things and that your inspections will pass. Concrete-encased electrodes (Ufer grounds) are worth specifying on every project — they're nearly free during concrete work and provide superior grounding.