Build a house tight enough and you need to ventilate it mechanically. Natural air leakage in a well-built home isn't enough to maintain indoor air quality. That's where energy recovery ventilators (ERVs) and heat recovery ventilators (HRVs) come in. Choosing the wrong one for your climate is a common mistake.
What They Do
Both ERVs and HRVs bring fresh outdoor air in and exhaust stale indoor air out. The magic is in the heat exchanger core — outgoing air transfers its energy to incoming air, recovering 70-85% of the heating or cooling energy. You get fresh air without throwing away the energy you've already paid to condition.
The Key Difference
An HRV transfers only heat (sensible energy). An ERV transfers both heat and moisture (sensible + latent energy). This moisture transfer is what makes the choice climate-dependent.
When to Use an HRV
In cold climates with dry winters and no significant cooling season, an HRV is the right choice. Cold climate homes struggle with excess indoor humidity in winter (from cooking, showers, breathing). An HRV exhausts that moist air without bringing moisture back in. It lets you control indoor humidity by diluting it with dry outdoor air.
When to Use an ERV
In hot-humid climates or mixed climates with significant cooling seasons, an ERV is usually better. In summer, outdoor air is more humid than indoor air. An ERV's moisture transfer means the incoming outdoor air gives up some of its moisture to the outgoing exhaust stream, reducing the humidity load on your AC system. In winter, it works in reverse — retaining some indoor moisture.
Sizing and Installation
ASHRAE 62.2 provides the ventilation rate formula: 0.03 × floor area + 7.5 × (number of bedrooms + 1). A typical 2,000 sq ft, 3-bedroom house needs about 90 CFM of continuous ventilation. Size the ERV/HRV to deliver this rate. Install dedicated supply and exhaust ductwork — don't try to share with the HVAC system unless using an integrated design.
Maintenance Matters
ERVs and HRVs have filters and cores that need regular cleaning. Dirty filters restrict airflow and reduce effectiveness. Cores can accumulate dust and moisture. Most units need filter cleaning every 2-3 months and core cleaning annually. Build maintenance access into your installation — if it's hard to service, it won't get serviced.
The Payoff
A tight house with proper mechanical ventilation outperforms a leaky house in every measurable way: energy efficiency, comfort, indoor air quality, moisture control, and durability. The ERV/HRV is the component that makes tight construction work for the occupants. Don't build tight without it.