The average home loses 20-30% of its conditioned air through duct leaks before it ever reaches the rooms it's supposed to heat or cool. If ducts run through unconditioned spaces like attics or crawl spaces, that lost energy is gone completely. It's the single biggest energy waste in most homes.
Where Ducts Leak
The worst leaks are at connections — where branch ducts meet the trunk line, where boots connect to registers, and especially at the air handler cabinet. Factory air handlers often leak significantly at panel seams and filter slots. Flex duct connections pulled loose from collars are extremely common. Every joint, seam, and connection is a potential leak point.
Supply Leaks vs. Return Leaks
Supply leaks dump conditioned air into unconditioned space — pure energy waste. Return leaks pull unconditioned air into the system — hot attic air in summer, cold crawl space air in winter. Return leaks also pull in dust, insulation fibers, and potentially mold spores. Both waste energy, but return leaks can also damage indoor air quality.
Pressure Imbalances
Leaky ducts create pressure imbalances throughout the house. If supply ducts are leakier than return ducts, the house becomes depressurized — pulling outdoor air in through every crack and potentially backdrafting combustion appliances. If returns are leakier, the house pressurizes, pushing conditioned air out. Either way, you lose energy and comfort.
Testing and Measurement
A duct blaster test measures total duct leakage and leakage to outside. The test pressurizes the duct system to 25 Pascals and measures airflow needed to maintain that pressure. New construction in most energy programs targets less than 4 CFM25 per 100 sq ft of floor area for total leakage. Many existing homes test at 2-3 times that level.
Sealing Methods
Mastic (duct sealant) is the gold standard for sealing accessible duct joints. Apply it liberally over every connection with a brush or gloved hand. Mastic doesn't dry out or crack like duct tape (which is terrible for duct sealing despite its name). For inaccessible ducts, Aeroseal technology seals leaks from the inside by blowing adhesive particles through the system.
Ducts in Conditioned Space
The best solution to duct leakage in unconditioned spaces is to eliminate it — put ducts inside the conditioned envelope. Run ducts in dropped ceilings, interior chases, or within conditioned basements instead of attics and crawl spaces. If ducts must be in an attic, consider bringing the attic inside the envelope with spray foam on the roof deck. Duct leakage into conditioned space doesn't waste energy.
The ROI Is Huge
Sealing ducts costs $500-2,000 for a typical home (professional service). Energy savings of 15-25% on heating and cooling bills are typical. Comfort improves dramatically — rooms that were always too hot or cold start performing. It's one of the highest-ROI improvements you can make to an existing home.