Every wall assembly has a temperature gradient — warm on one side, cold on the other. Somewhere in that gradient, the temperature drops to the dew point of the air that's diffusing through. If that dew point falls on a surface that can't dry, you get condensation. Predicting where this happens is fundamental to wall design.
What Is the Dew Point?
The dew point is the temperature at which air becomes saturated and water vapor condenses into liquid. At 70°F and 50% relative humidity, the dew point is about 50°F. If any surface inside your wall assembly drops below 50°F while exposed to that indoor air, condensation occurs on that surface.
Plotting the Temperature Gradient
Each layer of a wall assembly has a thermal resistance (R-value). The temperature drops proportionally through each layer based on its fraction of the total R-value. If your total wall is R-20 and the cavity insulation is R-15, the cavity represents 75% of the temperature drop. In a wall with 70°F inside and 10°F outside, the temperature at the exterior sheathing is about 25°F — well below the dew point.
Why Exterior Sheathing Gets Wet
In a standard cavity-insulated wall, the biggest temperature drop occurs across the insulation — leaving the exterior sheathing very close to outdoor temperature. In winter, this sheathing temperature is almost always below the dew point of interior air. Any air or vapor that reaches the sheathing will condense. This is why air sealing the interior is critical.
The Ratio Rule for Exterior Insulation
When adding exterior continuous insulation, there's a critical ratio: enough exterior insulation must be present to keep the sheathing above the dew point. The IRC Table R702.7.1 specifies minimum exterior insulation R-values by climate zone. In zone 5, you need at least R-7.5 exterior for a 2x6 wall. Less than this and the sheathing temperature can still drop below the dew point, creating condensation at the foam-to-sheathing interface.
WUFI and Hygrothermal Modeling
For complex assemblies, professional hygrothermal modeling software like WUFI simulates moisture behavior over a full year, accounting for rain, sun exposure, temperature swings, and material properties. It's the gold standard for evaluating whether a wall assembly will perform. For unusual assemblies or high-risk situations (double-stud walls, retrofit exterior insulation), a WUFI analysis can catch problems before they're built in.
Practical Takeaways
Keep these principles in mind: air leaks transport far more moisture than vapor diffusion, so air seal first. Never put two vapor barriers on opposite sides of an assembly — the wall can't dry. When adding exterior insulation, meet the minimum ratios for your climate zone. And if you're unsure about a wall design, model it before you build it. Fixing condensation problems after the wall is closed up is extremely expensive.